Chimney HoodUser & Installation Instructions
Method 2: Extraction throughan outside wallThe fan draws cooking fumes throughthe washable grease filter into theunderside of the hood, then the fumes
Wall fixing (figures 4 & 5A / 5B)• Drill 8 mm diameter holes as shown.• Using the screws and dowelssupplied with the appliance, fastenthe wall bra
Hood MeasurementsThe below table shows the varioushood measurements for this hood:The dimensions of the chimney piece(including the hood body) are as
InstallationElectrical connectionThis appliance is double insulated forsafety and therefore does not requirean earth connection to the mains inlet.The
Electricity supply230 - 240V ~ 50HzClassificationclass II metal encasedNoise level (External Venting)Position 3 56 dBAPosition 2 49 dBAPosition 1 42 d
Customer Care & ServicePlease keep this handbook in a safe place as the information inside may be ofuse should you sell, or pass on the appliance.
14Care & CleaningDo not use caustic pastes, abrasive clean-ing powders, products containing bleach,coarse wire wool or any hard implements,as they
15
GLEN DIMPLEX HOME APPLIANCESSTONEY LANE, PRESCOT, MERSEYSIDE, L35 2XW08 27136 01 © 08.20043LI0D2D302.5 D3
Thank you for choosing this appliance. Should you need any information or assistance, please call the number belowand the Customer Care Centre staff
User’s Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 5Introduction . . . . . . . . . . . . . . . . . . . . .
Thank you for buying this hood, we hopethat it makes an attractive and useful addi-tion to your kitchen.This handbook contains informationwhich will
3Figure 1Parts IdentificationViewed fromunderneathOutletadaptorinner chimneyextension pieceouter chimneyextension piecewallbracketadjustablesliderlamp
Figure 2A: hood controls:The controls work as follows:A - Neon lightB - OffC - Position 1D - Position 2E - Position 3F - Light switchFigure 2B: hood
Before cleaning or maintenance,switch off the electricity supply.Replacing a light bulb1. Switch off the electricity supply.2. Remove the grease filte
Regulations and standardsBefore you start please read instructionscarefully. All installations, service andrepair work must be in accordancewith loca
Method 1: Re-circulation (dualfiltration)The fan draws cooking fumes throughthe washable grease filters into theunderside of the hood, then throughthe